Skip to the cards
Air in the House

Whole house · stack · 6 quick cards

Exhaust, Supply or Balanced Ventilation

8 cards · By the Air in the House editors, from U.S. Department of Energy, Home Ventilating Institute, International Residential Code, Building America (PNNL) and other documents · how stacks are made · Updated · this stack links to businesses tied to our owners, and each link says how

  1. Exhaust, supply or balanced: which system fits?

    Exhaust only ventilation pulls stale air out and lets replacement air leak in; supply systems push outdoor air in, and balanced systems move equal amounts both ways.

    • The Department of Energy describes three whole-house strategies: exhaust, supply and balanced.
    • HVI, citing DOE, calls exhaust ventilation most appropriate for colder climates and supply ventilation best in hot or mixed climates.
    • Balanced systems suit all climates but need two fans and two duct systems.
    • Most energy recovery ventilators recover about 70–80% of outgoing-air energy (HVI).
    • Under the 2024 IRC, balanced airflow with supply ducts reaching each bedroom earns a 30% lower required rate.
    • Exhaust fans, dryers and hoods running together can backdraft a gas water heater or furnace; a pro's combustion safety test checks.
    A white ceiling exhaust grille above a side-by-side washer and dryer in a laundry room, towels stacked on a wire shelf next to a window
    AI-made picture, not a photo of a real house
  2. How does exhaust only ventilation work?

    Exhaust only ventilation runs a fan that pulls air out of the house, and replacement air seeps back in through leaks in the shell and any intentional inlet vents, as DOE explains. The house sits slightly below outdoor pressure while it runs.

    HVI describes the usual setup as one fan at a central exhaust point, and a better one as a fan ducted from rooms where pollutants start, such as bathrooms and kitchens. Under the IRC, a bathroom fan on continuous duty must move at least 20 cfm; the whole-house rate is set separately, as the ASHRAE 62.2 page explains.

    Turn over for the detail

    The weak spot is the replacement air, which takes the easiest path. HVI's summary of DOE guidance lists what can ride along: radon, crawl space mold, attic dust, fumes from an attached garage, and flue gases from a fireplace, water heater or furnace. In warm, humid climates the same suction can drag moist air into wall cavities (attached garage air covers the garage side).

  3. How does supply ventilation work?

    Supply ventilation uses a fan to push outdoor air into the house, so the house runs slightly above outdoor pressure and stale air leaves through leaks, fan ducts and any intentional vents. HVI notes it works best feeding the rooms people use most, such as bedrooms and the living room.

    The incoming air can be filtered for pollen and dust or dehumidified, and positive pressure helps keep soil gases and flue gases out. The drawback shows up in cold climates: warm, humid indoor air is driven into cold attics and walls, where it can condense and cause mold and decay.

    Turn over for the detail

    Winter supply air may need mixing with indoor air to avoid drafts. The 2024 IRC requires automatic or gravity dampers on these outdoor air openings (IRC chapter 11) so they close when the system is off. For an idea of what's sold, one place that carries duct and vent dampers, including manual balancing dampers, is Plumbing Supply and More (Plumbing Supply and More, owned by the people behind Air in the House).

  4. What makes a system balanced?

    A system is balanced when it brings in and exhausts roughly equal volumes of air, each with its own fan, so the house is neither pressurized nor depressurized (DOE). A typical design supplies bedrooms and living rooms and exhausts the kitchen, bathrooms and laundry.

    Controlling both airstreams means incoming air can be filtered, but two duct systems and two fans usually make it costlier to install and operate. Supply air reaches each bedroom through a small duct ending at a wall or ceiling grille; Plumbing Supply and More's registers and grilles category (Plumbing Supply and More, owned by the people behind Air in the House) shows the kinds of grilles and ceiling diffusers sold.

    Three whole-house strategies, side by side
    StrategyHow air movesHouse pressureClimate fit (HVI, citing DOE)Main caution
    Exhaust onlyFan pulls air out; leaks let air inSlightly negativeColder climatesCan pull in garage fumes, radon and flue gases
    Supply onlyFan pushes outdoor air in; air leaks outSlightly positiveHot or mixed climatesPushes humid indoor air into cold walls in winter
    BalancedTwo fans move about equal air in and outAbout neutralAll climatesTwo fans and two duct systems cost more
    Balanced with HRV or ERVSame, through a heat exchangerAbout neutralAll climates; HRV or ERV by climateFilters and core need regular care
    Turn over for the detail

    Add a heat exchanger and you have an HRV or ERV, recovering about 70–80% of the outgoing air's energy. The code rewards full ductwork: under 2024 IRC M1505.4.3, a balanced system with supply ducted to each bedroom and to a living, dining or kitchen area may run at a rate 30% lower than the table requires. See ERV vs HRV.

  5. Which ventilation strategy suits your climate?

    In broad terms, exhaust only ventilation fits cold climates, supply fits hot or mixed climates, and balanced systems fit anywhere (HVI). The logic is moisture: in cold weather you don't want humid indoor air pushed into cold walls, and in warm, damp weather you don't want humid outdoor air pulled into them.

    In Climate Zones 6, 7 and 8, the 2024 IRC settles it by requiring a heat or energy recovery ventilator. Elsewhere the house matters as much as the weather: an attached garage, a crawl space or an atmospherically vented water heater argues against running negative all day.

  6. Does exhaust only ventilation affect gas appliances?

    It can. Any system that pulls out more air than it brings in lowers indoor pressure, and that can backdraft a gas, oil or wood appliance that isn't sealed-combustion or power-vented, spilling flue gases, including carbon monoxide, indoors.

    HVI flags the moments when bath fans, range hoods and clothes dryers, which also depressurize the home, run at the same time as an exhaust ventilation system. The Building America Solution Center adds that a tighter house reaches a deeper negative pressure for the same exhaust. Big hoods raise the same issue (makeup air for range hoods).

    Turn over for the detail

    The check for this is a combustion safety test, also called a worst-case depressurization test, done by a qualified pro with every exhaust appliance running. If you're unsure, call a licensed pro. Keep up the annual professional inspection of fuel-burning appliances that CPSC urges, and install CO alarms on every floor and outside the bedrooms. CPSC counts more than 200 US deaths a year from accidental non-fire CO poisoning tied to consumer products.

  7. What should a contractor's plan show?

    A good plan names the strategy, the airflow and how both will be checked. Ask the installer for:

    • The strategy and why, tied to your climate, appliances and any attached garage.
    • The design airflow in cfm and the method behind it, the ASHRAE 62.2 formula or the IRC table, with any intermittent-run factor shown.
    • Fan ratings under HVI or AMCA test methods, at your duct's static pressure.
    • Intake and exhaust locations. The IRC keeps outdoor air intakes at least 10 ft from vents, chimneys, streets and parking areas (R325.4.1), with exhaust outlets kept away from opening windows and property lines.
    • Controls that allow a manual override and are labeled, as IRC M1505.4.2 requires.
    • Dampers, grilles, duct sizes and how flows will be measured at startup.
    • A combustion safety test before and after, if the house has any vented fuel-burning appliance.
    Turn over for the detail

    Local rules vary, so the contractor should confirm which code edition your building department enforces.

  8. Numbers behind the three strategies

    Exhaust, supply or balanced: the numbers70–80%: energy recovered by most ERVs and HRVs; 30%: lower rate for fully ducted balanced systems; 10 ft: intake distance from vents and streets; 20 cfm: continuous bath exhaust minimum. Source: HVI, citing DOE; ICC 2024 International Residential CodeExhaust, supply or balanced: thenumbers170–80%energy recovered bymost ERVs and HRVs230%lower rate for fullyducted balancedsystems310 ftintake distance fromvents and streets420 cfmcontinuous bathexhaust minimumSource: HVI, citing DOE; ICC 2024 International ResidentialCode
    Chart drawn by Air in the House from figures cited in this stack.

Quick cards

Short questions people ask next, one answer each.

  1. Is a bath fan running all the time enough whole-house ventilation?

    It can be, if the fan is rated for continuous duty and sized to the whole-house rate. One that runs only during showers is local exhaust.

  2. Do supply ventilation systems filter the incoming air?

    They can. With one outdoor intake, the air can be filtered for pollen and dust, or dehumidified, before it reaches the rooms.

  3. Can supply ventilation cause moisture problems in winter?

    In cold climates, yes. Pressurizing pushes humid indoor air out through gaps in walls and ceilings, where it can condense in the attic or outer wall layers.

  4. Will exhaust only ventilation raise radon levels?

    It can pull more soil gas, including radon, into a house under negative pressure. Test to find out; the radon section explains how.

  5. Why do balanced systems cost more?

    They usually need two fans and two duct systems. Energy recovery adds a core and controls, and more parts mean more upkeep.

  6. Can passive inlet vents help an exhaust only system?

    Adjustable wall or window inlets let replacement air arrive in chosen rooms instead of random leaks, but they don't remove the pressure risk to vented appliances.

Parts and pages this stack names

About these links: the people behind Air in the House also own Plumbing Supply and More, SoftPro Water Systems and Quality Water Treatment, and work with Central Plumbing & HVAC. Nobody pays to be mentioned here. Our notes on these cards are ours; what a linked page says is that business's own claim. Who owns this site

  • Duct and vent dampers

    Plumbing Supply and More · owned by the people behind Air in the House

    Parts an HVAC contractor picks and fits on a ventilation or duct job, shown so the names on a proposal make sense.

    Open Plumbing Supply and More
  • Registers, grilles and ceiling diffusers

    Plumbing Supply and More · owned by the people behind Air in the House

    Parts an HVAC contractor picks and fits on a ventilation or duct job, shown so the names on a proposal make sense.

    Open Plumbing Supply and More

Where these cards come from

Built from DOE's whole-house ventilation page, HVI's ventilation-types publication, the 2024 IRC (chapters 3, 11 and 15), PNNL depressurization guidance and CPSC carbon monoxide pages, read in October 2026. No brand comparisons, installed costs or combustion-test pressure thresholds.

  1. U.S. Department of Energy Department of Energy
  2. Home Ventilating Institute HVI
  3. International Residential Code IRC chapter 11
  4. International Residential Code 2024 IRC M1505.4.3
  5. Building America (PNNL) Building America Solution Center
  6. CPSC CO alarms
  7. International Residential Code R325.4.1

Cards are written by the Air in the House editors from the documents above and dated when they were last checked. How stacks are made